Impedance |
50 ohm |
|
Frequency Range |
0 to 18.0 GHz |
|
• for RG – 402 & RG 405 semi-rigid cable – 0 to 18.0 GHz |
|
• for flexible cable → max operation frequency of cable
per MIL-C-17 |
|
VSWR |
•
|
1.05 + 0.005 x f GHz max (straight) |
|
|
•
|
1.15 + 0.015 x f GHz max (right angle) |
|
|
|
RG – 402 (.141” OD.) → 1.05 + 0.005 x f GHz max |
|
|
|
RG – 405 (.085 “ OD.) → 1.05 + 0.005 x f GHz max |
|
|
|
RG – 58, 141, 142, 223 → 1.10 + 0.01 x f GHz max(straight) |
|
|
|
1.15 + 0.02 x f GHz max (right angle)
|
|
|
|
RG – 174, 188, 316 → 1.15 + 0.01 x f GHz max (straight) |
|
|
|
1.18 + 0.02 x f GHz max (right angle)
|
|
|
|
RG – 178, 196 → 1.20 + 0.020 x f GHz max (straight)
|
|
|
|
1.25 + 0.025 x f GHz max (right angle)
|
|
Voltage Rating |
•
|
RG – 402 (.141 “ OD.) → 500 volts rms max |
|
•
|
RG – 405 (.085” OD.) → 335 volts rms max |
|
•
|
RG – 58, 141, 142, 223 → 500 volts rms max |
|
•
|
RG – 174, 188, 316 →
335 volts rms max
|
|
•
|
RG – 178, 196 →
250 volts rms max
|
|
Dielectric Withstanding Voltage |
•
|
RG – 402 (.141 “ OD.) → 1,000 volts rms max |
|
•
|
RG – 405 (.085” OD.) → 750 volts rms max |
|
•
|
RG – 58, 141, 142, 223 → 1,000 volts rms max |
|
•
|
RG – 174, 188, 316 →
750 volts rms max
|
|
•
|
RG – 178, 196 →
500 volts rms max
|
|
Contact Resistance |
center contact = 3.0 Milliohms max |
|
outer contact
= 2.0 Milliohm max
|
|
RF Leakage |
-(90 – f GHz) dB min |
|
Insertion Loss |
0.04 dB maximum x _f GHz (straight)
0.06 dB maximum x _f GHz (right angle) |
|
Insulation Resistance |
5,000 Megohms min |
|
Mechanical & Environmental:
|
|
Mating |
1/4” – 36 threaded coupling |
|
Durability |
500 matings |
|
Coupling Nut Retention |
Min 60 Ibs |
|
Recommend Nut Mating Torque |
8 inch-pounds |
|
Cable Retention |
RG – 58, 141, 142, 223 → 40 Ibs min |
|
RG – 174, 188, 316 →
20 Ibs min |
|
Temperature Range |
-65 °C to 165 °C |
|
Vibration |
MIL-STD-202 Method 204 Test Cond. D. |
|
Salt Spray |
MIL-STD-202 Method 101 Test Cond. B. |
|
Temperature Cycling |
MIL-STD-202 Method 102 Test Cond. C. |